RTI uses cookies to offer you the best experience online. By clicking “accept” on this website, you opt in and you agree to the use of cookies. If you would like to know more about how RTI uses cookies and how to manage them please view our Privacy Policy here. You can “opt out” or change your mind by visiting: http://optout.aboutads.info/. Click “accept” to agree.
Risk adjustment, mode adjustment, and nonresponse bias analysis on quality measures from a long-term care hospital experience of care survey
Zuckerbraun, S., Deutsch, A., Eicheldinger, C., Frasier, A. M., Loft, J. D., & Clift, J. (2020). Risk adjustment, mode adjustment, and nonresponse bias analysis on quality measures from a long-term care hospital experience of care survey. Archives of Physical Medicine and Rehabilitation, 101(5), 841-851. https://doi.org/10.1016/j.apmr.2019.11.016
OBJECTIVES: To develop a patient risk adjustment model for experience of care (EOC) quality measures for long-term care hospitals (LTCHs) that includes mode of survey administration. To assess presence of nonresponse bias in the adjusted facility-level scores.
DESIGN: We tested 3 modes of collecting the EOC data: mail-only, mixed (ie, mail with telephone follow-up), and in-facility. This study used sequential modeling and impact analysis, specified a risk and mode adjustment model, and evaluated presence of nonresponse after adjustment.
SETTING: LTCHs.
PARTICIPANTS: Patients (N=1364) and 69 LTCHs.
INTERVENTION: Not applicable.
MAIN OUTCOME MEASURES: Risk and mode adjusted responses to 28 survey questions and 6 facility-level scores derived from survey responses.
RESULTS: Mode of data collection and patient risk variables (age, sex, overall health, overall mental health, marital status, education, race, and whether a proxy responded) were included in the model. Clinical variables were not significant. The in-facility mode was associated with significantly higher performance scores than the other modes. When the recommended risk and mode adjustment model was applied, nonresponse bias was not observed in any mode.
CONCLUSIONS: LTCH EOC data should be adjusted for patient risk variables including mode of data collection.